Process Control Instruments

Equipment suitable for measuring and controlling the main industrial process variables

Flow Totalizer

  • Pulse or Analog Input for Measure the Flow
  • Individual Display for Totalizer & Flow Rate
  • Upto 2-Relay Output with Retransmission & RS-485 Modbus Output Facility

8 Channel Scanner with RS-485 Communication

  • Universal Input ((J, J.1, K, K.1, PT-100, PT.1,R,S,E,N,T,B,C,L,U 0 - 10V DC,
    0 - 20mA DC, 4 - 20mA DC, 1 - 5V DC)
  • 4 Relay (NO-C-NC) 1C/O 5A@230V AC, 5A for resistive load
    with RS-485 RTU MODBUS
  • 4-Relay Output for Alarm and Tripping with Grouping Facility

Slim Signal isolators

  • Fix Analog Input & Output with Inbuilt Sensor Supply
  • Slim Size which Occupies Less Space in Panel
  • Available in Single and Dual Output with Higher Noise Rejection Ratio
  • 3-Way Isolation Input-Output, Input-Supply, Output-Supply
  • Size: (H)100mm x (W)17.5mm x (D)115mm -Dual output
  • Size: (H)100mm x (W)12.5mm x (D)115mm -Single output
  • Supply Voltage: 100-270V AC/24V DC (Factory Set)

Process Indicator

  • 4-Digit Process Indictor
  • Universal Input (4-20mA DC/0-20mA DC/0-10V DC)
  • Upto 3-Digit Resolution

Process controller

  • 4 Digit Process Controller with In-Built Sensor Supply
  • Universal Input (4-20mA DC/0-20mA DC/0-10V DC)
  • Upto 2-Relay & Transmitter Supply & RS-485 Modbus Output as per requirement
  • Size: (H)48mm x (W)48mm x (D)95mm
  • Supply Voltage: 100-270V AC

Jumbo Display Process indicator

  • 4-Digit, 4-Inch Red LED Display(Single/Dual Side)
  • Universal Input (4-20mA DC/0-20mA DC/0-10V DC)
  • Upto 3-Digit Resolution
  • Optional Relay and Retransmission Output Possible

Process controller

  • Universal Input: Works with Various Sensor Types (4-20mA DC, 0-20mA DC, 0-10V DC)
  • 4-Digit Display: Clear and Precise Readings
  • Built-in Sensor Power: Eliminates external power supply for sensors
  • Dual Relay Outputs: Controls Two Separate Devices 

4 Channel Scanner

  • Universal Input (J/K/RTD/4-20mA DC/0-10V DC/0-20mA DC)
  • 4-Relay Output for Alarm and Tripping with Grouping Facility
  • USB Data Logging & RS-485 Modbus Facility

Load Cell Controller

  • Accept  Multichannel mV Input from Load Cell  to Measuring the Load
  • 5-Digit Dual LED Display for Accurate Indication of Load
  • 2-Relay for Switching Alarm, Load with Built-in Load Cell Excitation Supply
  • Optional Analog Retransmission and RS-485 MODBUS Communication

Signal Isolator-Temperature Input

  • Accepts RTD Sensor Inputs
  • Choice of Single or Dual Outputs
  • Exceptional Noise Resistance
  • Robust 3-Way Isolation for Protection:
    • Input to Output
    • Input to Supply
    • Output to Supply

Jumbo Display Temperature indicator

  • Clear Display: 4-Inch, 4-Digit Red LED (Single or Dual Side)
  • Versatile Input: Works with J, K, or RTD Sensors
  • Flexible Output: Optional Relay and Retransmission Modules

8 Channel Scanner

  • Universal Input (J/K/RTD/4-20mA DC/0-10V DC/0-20mA DC)
  • 4-Relay Output for Alarm and Tripping with Grouping Facility
  • USB Data Logging & RS-485 Modbus Facility

Process indicators

  • 4-Digit Process Indictor
  • Universal Input (4-20mA DC/0-20mA DC/0-10V DC)
  • Size: (H)96mm x (W)96mm x (D)43mm
  • Supply Voltage: 100-270V AC

16 Channel Scanner

  • Versatile Input: Works with Various Sensor Types (J, K, RTD, 4-20mA DC, 0-10V DC, 0-20mA DC)
  • Extensive Control: 8-Relay Outputs for Alarms, Tripping, and Grouping
  • Data Management: USB Logging and RS-485 Modbus Communication

Signal Isolator

  • Dedicated Analog Input and Output
  • Choice of Single or Dual Outputs
  • Exceptional Noise Resistance
  • Comprehensive 3-way Isolation:
    • Input-to-Output
    • Input-to-Supply
    • Output-to-Supply

Current Scanner

  • 8 CT Input with Inbuilt 60A AC Current
  • Compact Size with 3-Digit Led Display
  • RS-485 Modbus Output

Voltage Transducer

  • Designed for AC Voltage Input
  • Provides Fixed Analog Output
  • Available in Single or Dual Output Configurations
  • Excellent Noise Rejection
  • Comprehensive 3-Way Isolation for Safety:
    • Input to Output
    • Input to Supply
    • Output to Supply

Process indicator

  • 4-Digit Process Indicator
  • Universal Input (4-20mA DC/0-20mA DC/0-10V DC)
  • Upto 3-Digit Resolution
  • Size: (H)48mm x (W)48mm x (D)46mm
  • Supply Voltage: 100-270V AC

Jumbo Display Programmable counters

  • Clear Display: Large 4/6-Digit, 4-Inch Red LED, Viewable From One or Both Sides
  • Versatile Input: Accepts Proximity Sensors or Micro Switches for flexible Control
  • Relay Output: Directly Controls Equipment or Devices for Automation

PROCESS & TEMPERATURE CONTROLLER

  • Universal Input (J/K/R/S/E/N/T/B/RTD/4-20mA DC/0-10V DC/0-20mA DC/0-75mV)
  • 5-Digit LED Display
  • 2-Relay Output
  • Analog Output (Retransmission & Controlling) & RS-485 Modbus Facility
  • Size: (H)48mm x (W)96mm x (D)75mm
  • Supply Voltage: 100-270V AC

Flow Totalizer

  • Pulse or Analog Input for Measure the Flow
  • Inbuilt Sensor Supply
  • Individual Display for Totalizer (8-Digit) & Flow Rate (5-Digit)
  • Upto 2-Relay Output with Retransmission/ Transmitter Supply (Anyone) & RS-485 Modbus Output Facility
  • Size: (H)96mm x (W)96mm x (D)54mm
  • Supply Voltage: 100-270V AC

Process indicator

  • 4-Digit Process Indicator
  • Universal Input (4-20mA DC/0-20mA DC/0-10V DC)
  • Upto 3-Digit Resolution
  • Size: (H)72mm x (W)72mm x (D)38mm
  • Supply Voltage: 100-270V AC

Current Transducer

  • Handles Current Transformer (CT) Inputs
  • Provides Fixed Analog Outputs
  • Offers Single or Dual Output Options
  • Boasts Exceptional Noise Resistance
  • Ensures Safety with 3-Way Isolation:
    • Input to Output
    • Input to Supply
    • Output to Supply

Signal Isolators

  • Fix Analog Input & Output
  • Available in Single and Dual Output with Higher Noise Rejection Ratio
  • 3-Way Isolation Input-Output, Input-Supply, Output-Supply
  • Size: (H)76mm x (W)28mm x (D)85mm
  • Supply Voltage: 100-270V AC/24V DC

Slim Signal Isolator

  • Fix Analog Input & Output With Inbuilt Sensor Supply
  • Slim Size Which Occupies Less Space in Panel
  • Available in Single And Dual Output with Higher Noise Rejection Ratio
  • 3-Way Isolation Input-Output, Input-Supply, Output-Supply

Process Indicator

  • 4 Digit Process Controller with In-Built Sensor Supply
  • Universal Input (4-20mA DC/0-20mA DC/0-10V DC)
  • Upto 2-Relay Output & Transmitter supply, Analog Retransmission( Optional) & RS-485 Modbus Output (optional)
  • Size: (H)96mm x (W)96mm x (D)54mm
  • Supply Voltage: 100-270V AC

This site uses cookies and related technologies for site operation, analytics, and third party advertising purposes as described in our Privacy and Data Processing Policy. You may choose to consent to our use of these technologies or reject non-essential technologies. To opt-out of sharing with third parties information related to these technologies, select "Decline All".