Process Control Instruments

Equipment suitable for measuring and controlling the main industrial process variables

Process Indicator

  • 4-Digit Process Indictor
  • Universal Input (4-20mA DC/0-20mA DC/0-10V DC)
  • Upto 3-Digit Resolution

CRYO – Panel AC Application

  • NTC Input for Temperature Sensing
  • Pulse/Door Input for Versatile Functionality
  • Powerful 20A Relay Output Controls Compressor Load
  • Dedicated 5A Relay for High/Low Alarm Functions
  • Convenient Touch/Keypad Module for User Interaction

Thumbwheel –On/Off Timer

  • 3-Digit Display, Time Set by Thumbwheel
  • Input Proxy/Micro Switch
  • Delayed On/Off
  • Range Hour/Minute/Second
  • With Power Fail Memory

Flow Totalizer

  • Pulse or Analog Input for Measure the Flow
  • Individual Display for Totalizer & Flow Rate
  • Upto 2-Relay Output with Retransmission & RS-485 Modbus Output Facility

8 Channel Scanner

  • Universal Input (J/K/RTD/4-20mA DC/0-10V DC/0-20mA DC)
  • 4-Relay Output for Alarm and Tripping with Grouping Facility
  • USB Data Logging & RS-485 Modbus Facility

16 Channel Scanner

  • Versatile Input: Works with Various Sensor Types (J, K, RTD, 4-20mA DC, 0-10V DC, 0-20mA DC)
  • Extensive Control: 8-Relay Outputs for Alarms, Tripping, and Grouping
  • Data Management: USB Logging and RS-485 Modbus Communication

8 Channel Scanner with RS-485 Communication

  • Universal Input ((J, J.1, K, K.1, PT-100, PT.1,R,S,E,N,T,B,C,L,U 0 - 10V DC,
    0 - 20mA DC, 4 - 20mA DC, 1 - 5V DC)
  • 4 Relay (NO-C-NC) 1C/O 5A@230V AC, 5A for resistive load
    with RS-485 RTU MODBUS
  • 4-Relay Output for Alarm and Tripping with Grouping Facility

CRYO - With Alarm Function

  • Single NTC input for temperature sensing.
  • 10A relay output for controlling compressor or heater load.
  • 10A alarm output or 12V DC buzzer for high/low temperature alerts.
  • 3-digit white/red display with 0.1 resolution for clear temperature indication.

Analog Din Rail Earth Leakage Relay

  • Range 30mA to 30A  AC
  • Programmable Set and Trip Delay by Knob
  • 1-Relay, 1-C/O,5A,230V AC
  • With Front key and Terminal Reset and Test Function

Signal Isolator-Temperature Input

  • Accepts RTD Sensor Inputs
  • Choice of Single or Dual Outputs
  • Exceptional Noise Resistance
  • Robust 3-Way Isolation for Protection:
    • Input to Output
    • Input to Supply
    • Output to Supply

Slim Signal Isolator

  • Fix Analog Input & Output With Inbuilt Sensor Supply
  • Slim Size Which Occupies Less Space in Panel
  • Available in Single And Dual Output with Higher Noise Rejection Ratio
  • 3-Way Isolation Input-Output, Input-Supply, Output-Supply

Jumbo Display Programmable counters

  • Clear Display: Large 4/6-Digit, 4-Inch Red LED, Viewable From One or Both Sides
  • Versatile Input: Accepts Proximity Sensors or Micro Switches for flexible Control
  • Relay Output: Directly Controls Equipment or Devices for Automation

Signal Isolator

  • Dedicated Analog Input and Output
  • Choice of Single or Dual Outputs
  • Exceptional Noise Resistance
  • Comprehensive 3-way Isolation:
    • Input-to-Output
    • Input-to-Supply
    • Output-to-Supply

Digital Time Totalizer-Hour Meter

  • 6-Digit Timer
  • Micro Switch/Limit Switch/Proximity Switch/230V AC Input (Factory Set)
  • Reset by Front Keypad and Remote
  • Range Hour/Minute/Second
  • With Power Fail Memory

4 Channel Scanner

  • Universal Input (J/K/RTD/4-20mA DC/0-10V DC/0-20mA DC)
  • 4-Relay Output for Alarm and Tripping with Grouping Facility
  • USB Data Logging & RS-485 Modbus Facility

Current Transducer

  • Handles Current Transformer (CT) Inputs
  • Provides Fixed Analog Outputs
  • Offers Single or Dual Output Options
  • Boasts Exceptional Noise Resistance
  • Ensures Safety with 3-Way Isolation:
    • Input to Output
    • Input to Supply
    • Output to Supply

Load Cell Controller

  • Accept  Multichannel mV Input from Load Cell  to Measuring the Load
  • 5-Digit Dual LED Display for Accurate Indication of Load
  • 2-Relay for Switching Alarm, Load with Built-in Load Cell Excitation Supply
  • Optional Analog Retransmission and RS-485 MODBUS Communication

Process controller

  • Universal Input: Works with Various Sensor Types (4-20mA DC, 0-20mA DC, 0-10V DC)
  • 4-Digit Display: Clear and Precise Readings
  • Built-in Sensor Power: Eliminates external power supply for sensors
  • Dual Relay Outputs: Controls Two Separate Devices 

Din Rail Earth leakage Relay

  • Bright 3+3 LED Display in Din Rail Mount
  • Range: 30mA to 30A AC
  • Programmable Trip Delay
  • 1-Relay, 1-C/O
  • With Front Key and Terminal Reset and Test Function

Power Supply 12V-8A

  • Power 96W
  • Efficiency > 85% @230V AC
  • Mounting DIN Rail
  • Material: Front Facia (ABS) & Enclosure (Aluminium)
  • Peak efficiency: Save energy with High-Performance Conversion and Adjustable Voltage.

CRYO -20A Single Output

  • Single NTC input for temperature sensing.
  • 20A Relay Output designed for compressor or heater loads.
  • 3-digit white/red display with 0.1 resolution for precise temperature monitoring.
  • Time-based defrost feature enhances functionality and efficiency.

Current Scanner

  • 8 CT Input with Inbuilt 60A AC Current
  • Compact Size with 3-Digit Led Display
  • RS-485 Modbus Output

On- Off Delay timer- Universal Supply and Time Range

  • Precise Timing: From 0.1 Seconds to 10 Hours, Delay Activations/Deactivations as Needed
  • On/Off Flexibility: Choose Between On-Delay or Off Delay Modes
  • Heavy-Duty Output: Control Devices with a Single 5A SPDT (2-C/O) Relay at 230V AC
  • Universal Power: Adapts to Various Supplies- 12-240V DC or 20-240V AC

Voltage Transducer

  • Designed for AC Voltage Input
  • Provides Fixed Analog Output
  • Available in Single or Dual Output Configurations
  • Excellent Noise Rejection
  • Comprehensive 3-Way Isolation for Safety:
    • Input to Output
    • Input to Supply
    • Output to Supply

Jumbo Display Process indicator

  • 4-Digit, 4-Inch Red LED Display(Single/Dual Side)
  • Universal Input (4-20mA DC/0-20mA DC/0-10V DC)
  • Upto 3-Digit Resolution
  • Optional Relay and Retransmission Output Possible

Jumbo Display Temperature indicator

  • Clear Display: 4-Inch, 4-Digit Red LED (Single or Dual Side)
  • Versatile Input: Works with J, K, or RTD Sensors
  • Flexible Output: Optional Relay and Retransmission Modules

This site uses cookies and related technologies for site operation, analytics, and third party advertising purposes as described in our Privacy and Data Processing Policy. You may choose to consent to our use of these technologies or reject non-essential technologies. To opt-out of sharing with third parties information related to these technologies, select "Decline All".